Key takeaways
6 min read
Key point 1
The top is the part of a block wall that takes the most water, and the cores carry it downwards.
Key point 2
A cap must cover the whole top, shed water, overhang the faces and keep its joints watertight.
Key point 3
With 3 m profiles there are far fewer joints than with short pieces bedded in mortar.
Key point 4
Measure the finished wall width: the ALU-CLICK® profile adds a 25 mm overhang on each side.
Key point 5
For a quote, send widths, runs, corners, T junctions, ends and colour.
In this article
An external concrete block wall takes water on its faces, but it suffers most at the top. The top of the wall is its only horizontal surface: water sits there instead of running off and, without a cap, goes straight into the masonry.
This guide explains what a wall cap has to do, how to measure a block wall to order one and how the ALU-CLICK® wall coping we make to measure is fitted.
Section 02
Why the Top of a Concrete Block Wall Needs a Cap
Hollow concrete block has two features that make it vulnerable at the top:
- The cores connect vertically. If they have not been filled, water that gets in at the top runs down inside the wall and shows up several courses lower, sometimes on the opposite face.
- Concrete is porous. Even with no open void, water standing on top soaks into the block.
The usual results are white efflorescence on the faces, mortar joints breaking down, spalling where there is frost and dirt streaks below the top. On fair-faced block with no render, they show sooner.
Section 03
What a Wall Cap Has to Do
Whether it is called a cap, coping or capping, the piece on top of the wall has four jobs:
- Cover the whole top, leaving no edge of the masonry exposed.
- Shed water outwards, so none stands on top.
- Overhang the faces of the wall so drips fall clear of the wall and don't stain it.
- Keep the joints between pieces watertight over time.
The Spanish building code, CTE DB-HS 1, section 2.3.3.7, requires parapets to be finished with copings or another solution with the same effect. For copings it describes a minimum slope of 10°, drips at least 2 cm from the wall face and watertight joints. Other countries have their own rules, so check the one that applies to your project. These conditions are resolved in the project detail: choosing a particular material does not meet them on its own.
Section 04
Block Cap, Coping Stone or Aluminum Coping: What Changes
Precast block caps, concrete or ceramic copings and natural stone are bedded in mortar, piece by piece. An aluminum wall coping is fixed dry on top of the wall. The practical difference is the number of joints and how each one is sealed.
An example: on a 20 m wall, 50 cm pieces leave 39 joints. With 3 m ALU-CLICK® profiles there are 6, each with the expansion gap given in the technical sheet.
If you are choosing the material, the full comparison of shape, joints, fitting and cost is in metal, concrete or ceramic coping: how to choose.
Section 05
How ALU-CLICK® Is Fitted on a Block Wall

The system has two parts: a 70 mm grooved bracket with a built-in bituminous seal, fixed to the top of the wall, and a 3 m lacquered aluminum profile that clips onto it. There is no silicone and no visible fixing.
The technical sheet describes fitting in four steps:
- Line up the ALU-CLICK® brackets on the wall.
- Fix each bracket to the wall.
- Fit the profile by rotating it from the outside towards the inside until it clicks.
- Leave a 4 mm gap between pieces when fitting in summer and 8 mm in winter, for the expansion of the aluminum.
Corners, junctions and ends are made with factory pieces: 90° external and internal mitres, a T piece where two walls meet and an end cap for free ends.
You can check the system technical sheet and the bracket drawing before finalising the detail.
Section 06
How to Measure a Block Wall to Order the Cap

The profile is made to the width of the wall and overhangs 25 mm on each side, with a 45 mm drop. That is why you measure the real width of the finished wall, not the bare block: render or cladding adds width to each face.
To get the order right first time:
- Width of the wall top, measured at several points along the run. If it varies, note each section.
- Length of each straight run, separately.
- Corners: how many 90° external and internal mitres. Internal ones in courtyards and set-backs are the ones most often forgotten.
- T junctions between walls and free ends that need an end cap.
- Colour: RAL 7016 (anthracite grey), RAL 9006 (white aluminum), RAL 9003 (white) or RAL 7022 (dark grey), the four standard colours.
- Condition of the wall top: whether it is level, whether it is fair-faced and whether there is an old coping underneath.
The technical sheet gives a profile width of 70 to 600 mm.
Section 07
What to Send for a Quote
For a project with several walls, the quickest way is to send the roof or site plan with widths and lengths dimensioned, or a list of runs with their corners, junctions and ends. With that, the quote is ready within 24 working hours.
The form on the ALU-CLICK® wall coping page asks for each run's wall width, metres, mitres and end caps, and lets you attach the drawing or measurements. Note T junctions and any special detail in the comments.
Section 08
Common Mistakes on Site
- Leaving the wall top unprotected during the build. Until the cap is on, rain goes straight into the cores.
- Measuring the block instead of the finished wall. The render changes the width to cover.
- Counting only external corners and forgetting internal mitres and T junctions.
- Ignoring the gap between pieces. Without the 4 or 8 mm from the sheet, the aluminum has no room to expand.
- Fitting on an uneven wall top. Level it first, because the lacquered profile shows any unevenness.
- Assuming that filling the cores solves the problem. It helps on the top course, but filled concrete still absorbs the water that stands on top.
FAQ
Frequently asked questions
Can an aluminum wall coping be fitted over an existing concrete coping?+
Yes. The ALU-CLICK® brackets are fixed on the existing top without removing the old coping, as long as it is sound and level. In that case, measure the existing coping, not the wall.
Do the block cores need filling before capping?+
Filling the top course helps, especially on freestanding walls, but it does not replace the cap: filled concrete is still porous and absorbs the water that stands on the top of the wall.
What cap width does a block wall need?+
The width of the finished wall, including render or cladding, not the bare block. The ALU-CLICK® profile is made to that size and adds a 25 mm overhang on each side, with a 45 mm drop.
Does the ALU-CLICK® coping have a slope?+
No. It is a flat lacquered aluminum profile with a 45 mm vertical drop on each side. If the project needs the slope and drip that the Spanish CTE DB-HS 1 describes for copings, or that your local rules require, that detail is resolved in the project before ordering.
What colours are available?+
Four standard colours: RAL 7016 (anthracite grey), RAL 9006 (white aluminum), RAL 9003 (white) and RAL 7022 (dark grey).
Related product

ALU-CLICK®
Wall Copings
Polyester-coated aluminium wall copings with the silicone-free ALU-CLICK® system
Request a quote
Contact usShare