Key takeaways
4 min read
Key point 1
Send a single list of every chimney on the project, grouped by stack size.
Key point 2
For each size, give the external width and length of the stack, quantity, finish and whether it is static or Serie E.
Key point 3
The standard height is fixed at 500 mm; width and length are made to measure.
Key point 4
Motorised chimneys need a minimum stack size that depends on the motor.
In this article
A housing development almost never has a single chimney size. The masonry stacks on the roof usually come in several sizes, each repeated a number of times, and sometimes one of them serves mechanical extraction. If the request for quote arrives with all of that in order, the quote comes back quickly and without back-and-forth.
This guide explains what information the manufacturer needs to quote the VENTUM® chimney caps for a whole project, and how to organise it.
Section 02
One List per Project, Not One Enquiry per Chimney
The most practical approach is to send a single list of every chimney on the roof, grouped by size. Each line is one stack type and how many there are. That way everything is quoted together and it is easier to check nothing is missing.
If the project has several phases or blocks, show that in the same list. It helps plan production and delivery to site for each part.
Section 03
What Each Line Needs
External size of the chimney stack, width and length, in millimetres. The cap is made to fit the stack, so give the exact size of the finished stack. We already allow 3 mm of clearance. If two opposite faces measure differently, always give the larger one.
Number of units for each size.
Finish. Powder-coated aluminium in RAL 9005, 7016, 9006, 7022 or 9003, or bright AISI 316 stainless steel. If every chimney is the same colour, say so once.
Static or motorised. The standard VENTUM ventilates by the Venturi effect, with no motor. If any chimney serves bathroom or kitchen extraction, say which ones need the mechanical Serie E version.
Special pieces, if any. A blind face where the stack sits against a wall, a height other than standard, or a non-rectangular shape. Irregular shapes need a dimensioned sketch with sizes and angles.
An example of what the list can look like:
| Type | External stack size (mm) | Units | Finish | Version |
|---|---|---|---|---|
| A | 600 × 600 | 12 | RAL 7016 | Static |
| B | 720 × 840 | 6 | RAL 7016 | Static |
| C | 540 × 540 | 4 | RAL 7016 | Serie E |
The sizes in the example are illustrative. Yours come from the roof plan or from measuring the stacks already built.
Section 04
The Cap Being Quoted
The VENTUM technical sheet fixes the dimensions that do not change from one chimney to the next. The standard overall height is 500 mm, with 6 horizontal louvres, a usable height of 405 mm and a 95 mm base. What is made to measure is the width and length.

It is made in 1.2 mm AL. 3005 H44 powder-coated aluminium or 0.8 mm AISI 316 stainless steel. It can have a removable face for easier maintenance and, on request, can be made in special heights.
Section 05
Chimneys with Extraction: Serie E
Serie E houses one or more motors, depending on the airflow to be extracted. Motor power does not depend on the external size of the stack, but each motor needs a minimum stack size. The technical sheet gives these minimums:
| Motor | Minimum stack size |
|---|---|
| HRB / 4-200 | 300 × 300 mm |
| CRHB / 4-250 | 445 × 445 mm |
| CRHB / 6-315 | 540 × 540 mm |
| CRHB / 6-355 | 610 × 610 mm |
For these chimneys, state the airflow to be extracted or the number of ducts reaching each one. The installation also needs an electronic voltage regulator to set the motor power.
Section 06
Lead Times and Delivery to Site
Standard stock products ship within 24 to 48 working hours. Made-to-measure orders or special finishes have a delivery time of 8 to 12 working days, production included. We can ship directly to site anywhere in the UK and Ireland.
Section 07
How to Send the Request
On the VENTUM® chimney caps page, the form takes several lines with quantity, length and width, and lets you attach the roof plan or an Excel list. The quote is prepared within 24 working hours.
Before sending it, you can check the VENTUM® technical sheet for the fixed dimensions and available versions.
FAQ
Frequently asked questions
Which size do I give, the flue or the stack?+
The external size of the finished chimney stack, width and length. The VENTUM® cap is made to fit the stack and we already allow 3 mm of clearance.
Can different chimney sizes go in the same quote?+
Yes. On a development the usual approach is a list of each stack size and its quantity. The form takes several lines and lets you attach the plan or an Excel file.
When is Serie E needed?+
When the chimney serves mechanical extraction, for example from bathrooms or kitchens. Each motor needs a minimum stack size, from 300 × 300 mm for the smallest to 610 × 610 mm for the largest.
How long does an order take?+
Standard stock products ship within 24 to 48 working hours. Made-to-measure orders take 8 to 12 working days, production included, with delivery to site anywhere in the UK and Ireland.
Related product

VENTUM®
Made-to-Measure Chimney Caps and Cowls
Made-to-measure chimney cap, static and mechanical
Request a quote
Contact usShare




