VENTUM®

Made-to-measure chimney caps and cowls

Made-to-measure chimney cap, static and mechanical

Request a quote

+50

Years of experience

ISO 9001

Certified

+30.000

Projects completed

NewsVENTUM® surpasses 200,000 units manufactured

Available standard finishes

Black · RAL 9005

Colour

Installations

On site

Anti-downdraught design

Chimney caps installed on construction sites for decades

Made-to-measure anti-downdraught cap. Direct installation, no on-site adjustments.

Made-to-measure and special caps

We manufacture chimney caps, cowls and terminals outside the standard catalogue: non-rectangular shapes, special sizes, custom finishes and technical solutions for unique projects, including caps for masonry chimneys and concrete flues.

Available finishes

Black

RAL 9005

Anthracite Grey

RAL 7016

Dark Grey

RAL 7022

Natural

RAL 9006

White

RAL 9003

AISI 316 Stainless Steel

Brillante

We also manufacture to order in any RAL chart colour, with a surcharge.

Technical specifications

Material
Polyester-coated aluminium alloy 3005 H44 AISI 316 stainless steel
Thickness
1.2 mm aluminium 0.8 mm stainless steel
Width and length
Made to measure
Maximum temperature
80 °C continuous
Certification
ISO 9001:2015
Standard finish
Black RAL 9005, Anthracite grey RAL 7016
Optional finishes
Available with surcharge, per RAL chart

Drawings

Dimensional drawingPDF
2D drawingPDF
Ventilation systemPDF
Extraction operationPDF

Request a quote

Attach drawings or documentation (optional)

VENTUM® range

Static or mechanical chimney cap: which VENTUM® each flue needs

We make the VENTUM® cap to the size of the chimney's masonry housing, in two versions. The choice depends on what the flue does: natural ventilation or forced extraction.

Series C

Static ventilation

For kitchen hoods, gas boilers and open fireplaces. The louvres are designed on the Venturi principle to create negative pressure inside the flue, which keeps natural ventilation going and prevents backdraught, with no motor.

Series E

Mechanical extraction

For forced ventilation of bathrooms and kitchens. It houses one or more motors sized to the airflow to be extracted, independently of the housing's outer dimensions. The installation must include an electronic voltage regulator to set the motor's output.

Series E motors

Swipe to see all columns →

Series E motors
ModelAirflowMinimum inner housingMax. powerSound pressure
HRB/4-20077 l/s300 × 300 mm35 W53 dB
CRHB/4-250170 l/s445 × 445 mm52 W58 dB
CRHB/6-315300 l/s540 × 540 mm69 W48 dB
CRHB/6-355454 l/s610 × 610 mm87 W58 dB

Reference airflow values from the catalogue; motor selection depends on the required airflow and installation conditions. 230 V motors.

Sizes and ordering

How to measure the chimney housing and order your VENTUM®

Dimensioned elevation of the VENTUM®: 500 mm overall height and 95 mm base plinth
Front elevation · overall height 500 mm · plinth 95 mm
Plan size
Made to the chimney housing (length × width)
Standard overall height
500 mm
Effective height
405 mm
Base plinth
95 mm
Louvres
6 horizontal louvres
Special heights and shapes
On request

What we need for your order

  1. 1

    Length and width of the chimney housing, measured exactly: we already allow 3 mm of clearance. If two opposite sides differ, give the larger one.

  2. 2

    Static or mechanical version. For mechanical, the airflow to be extracted or the number of ducts.

  3. 3

    Finish: polyester-coated aluminium in RAL 9005, 7016, 7022, 9006 or 9003, any other RAL colour on request, or bright AISI 316 stainless steel.

  4. 4

    The site's postcode. We deliver direct to site.

For irregular caps, send us a dimensioned sketch with measurements and angles.

Request a quote

Before fitting

How to finish the chimney housing

Recommendations from our technical catalogue for preparing a housing for bathroom and kitchen ventilation.

  1. 01

    One duct per room

    Run a separate duct up to the roof from each bathroom and kitchen, to avoid noise, odours and ventilation problems between dwellings.

  2. 02

    20 cm below the top

    Stop the ducts 20 cm below the top edge of the housing and seal them to each other with polyurethane foam, so that only the air inside the ducts is extracted.

  3. 03

    A solid top

    Concrete the last three courses of brickwork solidly, preferably with reinforcement, so strong wind pressure cannot pull them off.

  4. 04

    No masonry work to fix

    The VENTUM® base fixes in place without any masonry work and acts as a drip edge. Each cap comes with 6 × 50 mm hex-head screws and nylon plugs.

Manufacturing details

  • Parts joined with expanding press-fit points, no welding.
  • No sharp edges at the corners.
  • Optional removable side for easier maintenance.
  • Within 2,000 m of the sea, we recommend bright AISI 316 stainless steel.
  • Large sizes for lift shafts, light wells, car parks or screening air-conditioning units, with no internal walls to reduce the negative pressure.

Frequently Asked Questions